

Why SUNISTA for HVAC
A group diversified into various segments now led by a young team of professionals from gateway of pharma i.e Mumbai.
Team Sunista is consist of young qualified engineers hails from few of the parent renowned organisations in the HVAC sector. They bring extensive technical knowledge & rich experience of executing projects in different sectors across India as well as overseas. The team is having the quality to assist the requirement from design stage till execution of complete project. We are backed by our own consultancy team & flexible enough to work as per consultants guidelines. As the project get commissioned the group is committed to provide services for a certain time frame decided which helps the customer engineering team to get familiar with the system installed. The group also provides training programmes on new technology in HVAC system with its channel partners across the Indian sub-continent.

Validation & Qualification in HVAC system
The safety of personnel and efficacy of the material including raw ingredients, in-process goods and finished products as well as machineries in the pharmaceutical industry is majorly impacted by the air ventilation quality within the industry.
HVAC system stands for Heating, Ventilation and Air Conditioning system, which ensures the optimum quality of air environment as directed by regulatory authorities. The performance of HVAC system is ascertained by conducting validation of this system within specified duration. Validation of HVAC system is achieved at three levels such as installation qualification
(IQ), operational qualification (OQ), and performance qualification (PQ); Which is subject to provide documented evidence about the accuracy of results produced by it.
The validation of HVAC system involves systemized and assembled documents of its functional specifications such as design drawings, plans, and specifications; followed by validation master plan involving testing, adjusting, and balancing (TAB); and finally, the start-up reports. The parameters analysed are air flow velocity, air flow pattern, air changes per hour,
filter leak test, particle count, viable monitoring, filter integrity test, pressure difference, recovery test for temperature and humidity, temperature and humidity uniformity, and fresh air determination.
Compliances Followed:
• Controlled Conditions in accordance with Schedule M ,GMP , WHO and FDA
   standards.
• European Good Manufacturing Practices (EuGMP).
• Design Standard Followed by us:-
• ASHRAE (The American Society of Heating, Refrigerating and
   Air-Conditioning Engineers)
• SMACNA (Sheet Metal and Air Conditioning Contractors’ National Association)
• NFPA (National Fire Protection Association)
• IECC (International Energy Conservation Code)

